کلمپ متر PRO2S مدل P2-C65
DC VOLTAGE
Range | Resolution | Accuracy |
10V | 1mV | ±(0.8% reading + 3 digits) |
100V | 0.01V | |
600V | 0.1V |
-Maximum input voltage : 600V DC or 600V AC effective value.
-Minimum measuring voltage : 0.5V DC or 1V AC
AC Voltage
Range | Resolution | Accuracy |
10V | 1mV | ±(0.8% reading + 5 digits) |
100V | 0.01V | |
600V | 0.1V |
-Maximum input voltage : 600V DC or 600V AC effective value.
-Minimum measuring voltage : 1V AC
-Frequency response : 50HZ-60HZ true effective value
Alternating current
Range | Resolution | Accuracy |
10V | 0.001A | ±(0.3% reading + 6 digits) |
100V | 0.01A | |
600V | 0.1A |
-Maximum input current : 600A
-Frequency range : 50~ 60 Hz
-Response : true effective value
Frequency
Clamp head frequency measurement (pass A file ):
Range | Resolution | Accuracy |
60Hz | 0.1Hz | ±(2.0% reading + 10 digits) |
1000Hz | 0.001kHz |
Measuring range : 40Hz ~ 1000Hz
Input signal range : <1AAc (effective value)
Pass V file:
Range | Resolution | Accuracy |
60Hz | 0.1Hz | ±(2.0% reading + 10 digits) |
1000Hz | 0.001kHz |
Measuring range :40Hz ~ 1000Hz
Input signal range :> 0.8V AC (effective value)
Resistance:
Range | Resolution | Accuracy |
9.999KΩ | 1Ω | ±(1.0% reading + 3 digits) |
99.99KΩ | 10Ω | |
999.9KΩ | 100Ω | |
9.999MΩ | 1KΩ |
Open circuit voltage : about 0.4V
Overload protection : 250V DC or AC (effective value)
Diode test
Range | Resolution | Accuracy |
0.001V | Display approximate diode forward voltage value |
Reverse DC voltage is about 2.5V
Overload protection : 250V DC or AC (effective value)
line continuity test
Range | Resolution | Accuracy |
1Ω | if the resistance of the tested circuit is less than 30 Ω, the buzzer inside the meter will sound |
Capacitance
Range | Resolution | Accuracy |
999uF | 100nF | ±(3.5% reading + 10 digits) |
9999uF | 1uF | ±(4.5% reading + 10 digits) |
Overload protection : 250V DC/AC
نقد و بررسیها